5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V
Sale!

5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

Original price was: £293.51.Current price is: £73.37.

SKU: GK3000-4T0037G Category:

Description

5 hp (3.7/4 kW) variable frequency drive, three phase 230V, 400V, 480V for selection, manufacturer direct sale.
Specification:

Basics Model GK3000-4T0037G/ GK3000-2T0037G
Capacity 5 hp (3.7 kW)
Shipping weight 3 kg
Dimension 236*130*176 mm for GK3000-4T0037G/ 272*172*182 for GK3000-2T0037G
I/O Feature Rated current 9A at 380V ~ 480V, 13A at 220V ~ 240V
Input voltage 3 phase 230V /400V /480V AC ±15% (Optional)
Input frequency 50Hz/ 60Hz
Output voltage 3 phase AC 0~input voltage
Output frequency 0Hz~1000Hz
Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control Feature Control mode V/F control;
Sensorless vector control;
Communication RS485
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity 5%-95%, without condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

Tips: Variable Frequency Drive Overvoltage
Overvoltage alarm is generally present at downtime, the main reason is that the deceleration time is too short or the braking resistor and the braking unit are problematic. For example, a 5hp VFD displays “OU” when shutdown. Before repairing the VFD, should make sure the reason for “OU” alarm is what. Here is because during the VFD deceleration, the speed of the motor rotor winding cutting the rotation magnetic field becomes fast, the rotor electromotive force and current increases, so that the motor is in power generation state. The feedback energy flows to DC part through the diode, which connects in parallel with high-power switch tube in inverting part, and finally causes by DC bus voltage increase. So, should focus on checking the brake circuit. After measuring the discharge resistance, find there’s no problem. In the measurement of the brake tube find it breakdown. Replace it and power on, even fast parking have no problem.