Description
30 kVA single phase frequency converter, make your appliances compatible with international power systems, change single phase 240V 50Hz to 120V 60Hz (vice versa) in one step by inner step up & step down transformer.
Specification:
| Model | HZ-50-1130 | |
| Capacity | 30 kVA | |
| Dimension | 770*580*1140mm | |
| Weight | 270 kg | |
| Input | Voltage | 1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *) |
| Frequency | 50 Hz, 60 Hz | |
| Output | Voltage, current | 110V Setting (Low grade): 0-150V, 250A |
| 220V Setting 0-300V (High grade): 0-300V, 125A | ||
| Load stabilization Rate | ≤±1% | |
| Frequency | 50Hz, 60Hz up to 400Hz adjustable Note: -When the output is 400Hz, the load capacity can only reach 50% of the rated capacity. -When the output is ≤120Hz, the load capacity can reach 100% of the rated value. -You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option. |
|
| Frequency Stability | ≤±0.01% | |
| Harmonic Distortion | Pure Sine Wave ≤2% | |
| Frequency meter | 4 digit, digital frequency meter, resolution 0.1Hz/Step | |
| Voltmeter | 4 digit, digital voltage meter, resolution 0.1V | |
| Ammeter | 4 digit, digital ammeter, resolution 0.1A | |
| Watt meter | 4 digit, digital Watt meter, resolution 0.1W | |
| Protection | With overload, short circuit, over temperature | |
| Instantaneous power failure protection and alarm device | ||
| Working Environment | Temperature | 0 – 40 deg.℃ |
| Humidity | 0 – 90% (Non condensation) | |
| Warranty | 18 months |
Tips: Maintenance method of the frequency converter
- Ensure correct voltage control, conduct sequence protective action test.
- Pay attention to clean thoroughly the dust in the cooling air duct and air filter.
- Ensure that the balance of the output voltage during the separate operation of the frequency converter meets the standard.
- Guarantee the protection and display loop of the frequency converter to have no abnormal condition.
- Conduct one regular inspection of the frequency converter equipment every year.
- Inspect if there is any loose screw spike, plugin and other equipment components.
- Measure the waveform of the driving circuit to check if there is any distortion, if the UVW phase waveform is the sine wave.
- If it is allowed, the oscilloscope can be used to measure the stability of the switching power supply output voltage.
- It is required to wipe the conductor and insulator with alcohol in time, so as to ensure the cleaning degree.