10 HP 8 Ton Air Cooled Industrial Water Chiller
Sale!

10 HP 8 Ton Air Cooled Industrial Water Chiller

Original price was: £2,854.00.Current price is: £298.98.

SKU: ATO-IWC-10HP Category:

Description

10 HP portable water chiller machine for sales, 8 ton refrigerating capacity, works in three-phase four wire 50Hz or 60Hz power supply, 240V/ 400V/ 480V AC voltage are optional. It is widely used in industrial injection molding machines, film-blowing machines, laser cutting, chemical and pharmaceutical fields, etc.

Features

  • Adopted high-quality compressors and pumps to ensure safe & quiet running, power saving and durable service life.
  • Employed microcomputer with easy operation which can control the temperature within 3℃ to 45℃ precisely.
  • Unique design for condenser and heat-dispersion unit results in excellent heat-exchange effect.
  • Equipped with electrical current overload protection, high & low-pressure switch, and electrical timer delay safety device. It will alarm to display faulty when any malfunction occurs.
  • Built-in stainless steel insulated water tank, durable and easy to clean.
  • Complete safety devices including power reverse phase, power short phase and anti-freeze protection.
  • Ultra low-temperature type of chiller can reach below -60℃.

Parameter

Model ATO-LC10A
Cooling Capacity 8 ton
Number of Compressors 2
Compressor Total Power 10 HP
Refrigerant R22 / R407C (Optional)
Evaporator Type Spiral type / Tube-in-shell type (Optional)
Condenser Type Finned
Cooling Type Air-cooled
Number of Fans 2
Single Fan power 0.25kW
Number of Cooling Water Inlet/Outlet 1 group
Cooling Water Inlet/Outlet Size DN40
Water Tank Capacity 145L
Pump Power 1 HP
Pump Flow 200L/min
Pump Lifts 13M
Power Supply 3-phase 4-wire AC 208V/60Hz, 220V/60Hz, 240V/60Hz, 380V/50Hz, 400V/50Hz, 415V/50Hz, 480V/60Hz (Optional)
Control Voltage 1-phase AC 220V (L+N)
Total Power 8.8kW
Wires Specifications 4x6mm2
Chilled Water Temperature Range 5℃~35℃
Inlet/Outlet Water Temperature Difference 3℃~8℃
Condensation Temperature ≤ 35℃
Certification CE
Dimension L*W*H=1500*730*1400mm
Net Weight / Gross Weight 450kg / 500kg

Shipping Way of ATO Water Chiller

Just confirm the shipping way by email when place your order.

1. Ship by Air: The compressed refrigerant inside the chiller is a dangerous item with the possibility of explosion, so it needs to release the compressed refrigerant before transportation. (It means that water chiller without refrigerant when choosing this shipping way. After the machine arrives at your destination, you need to add refrigerant by local professionals, the process is as simple as adding refrigerant for ordinary air conditioners). Delivery time is about 15-30 days.

2. Ship by Sea: The transportation time is longer (about 40-55 days), and there is no need to add refrigerant after the equipment arrives at the destination.

Note:

1. The “cooling capacity” is tested based on the inlet and outlet water temperature of freezing is 12℃/7℃, and the inlet and outlet water temperature of cooling is 30℃/35℃.

2. Conversion of units: 1 ton cooling capacity=3024kcal/hr, 1kcal/hr=3.969BTU/hr, 1HP=0.735kW=2580kcal/hr

Evaporator Types

Type 1: Water Tank with Coil

  • Integrated Design: The industrial water chiller features a built-in open-top water tank with an integrated coil, providing a compact and self-contained cooling solution.
  • Sealed Circulation: The water circuit operates in a sealed loop, ensuring stable performance and preventing contamination.
  • Direct Connection: The air-cooled water chiller supports direct connection to equipment requiring cooling, with no external tank needed.

Type 2: Shell and Tube

  • Tankless Configuration: This water chiller is designed without an internal water tank and relies on an external open water tank for operation.
  • Application: Specifically suitable for cooling external open water tanks, pools, or reservoirs in industrial and commercial applications.

Water Chiller Structure Diagram

Compressor High-pressure gauge Condenser Dry filter
Expansion valve Water supply Evaporator Low-pressure gauge
Water tank Drain Refrigerated water Pump

Tips: Can an industrial water chiller be cleaned with acid?

In normal applications, the chiller requires regular and scientific cleaning, which is also an indispensable part of maintenance. Mainly condensers, evaporators, various pipes, etc., especially the condensers and evaporators of water-cooled type chiller, must be regularly cleaned.

Pickling can be applied as a cleaning method. However, the degree of dilution of the acid solution and the type of acid solution need to be considered. Basically, almost all condensers can be cleaned using acid. In addition, it is necessary to consider whether the components of the water chiller to be cleaned are a certain part or the entire cycle operation system. These two aspects are completely different.

In case of cleaning the circulating operation system, it is necessary to ensure that the system is completely closed, and connect the cleaning pump, liquid distribution tank and relevant valves of the refrigerator. If it is cleaned separately, it is necessary to remove the condenser, and then add the diluted acid into it. It must be filled to achieve the corresponding cleaning effect. The reason why it is necessary to clean the chiller is that there are many parts in the chiller that will affect the normal operation of the whole water chiller.

Reviews

There are no reviews yet.

Be the first to review “10 HP 8 Ton Air Cooled Industrial Water Chiller”

Your email address will not be published. Required fields are marked *