9V DC Signal Relay, SPDT, 3A
Sale!

9V DC Signal Relay, SPDT, 3A

Original price was: £18.99.Current price is: £5.69.

SKU: ATO-SR-W38DC9V Category:

Description

Low price 9V signal relay with full-turn and full-negative electromagnetic coil is more stable and precise.

Features

  • 3A contact switching capability.
  • Contact form: SPDT (1C).
  • High sensitive type, coil power is 200mW/360mW/450mW.
  • Standard DIP construction terminal.
  • Ultra – small type, gold – plated contacts.
  • Suit for complete machine wave soldering and integral cleaning process.
  • Main applications: Electric power protection, automation, communication.

Specification

Model ATO-SR-FH38DC9V
Type Standard Type Sensitive Type High Power Consumption Type
Coil Parameters (23℃) Nominal Voltage DC 9V
Nominal Power 360mW 200mW 450mW
Pick-up Voltage ≤6.75VDC ≤6.75VDC ≤6.75VDC
Drop-out Voltage ≥0.45VDC ≥0.45VDC ≥0.45VDC
Rated Current 40mA 22.2mA 50mA
Coil Resistance 225Ω 450Ω 180Ω
Max Voltage DC 11.7V DC 11.7V DC 11.7V
Contact Parameters Contact Form SPDT (1C)
Contact Resistance (Initial) ≤100mΩ (6VDC 0.1A)
Contact Material AgNi + Gold Plating
Rated Value Rated Load (Resistance Load) 1A 240VAC/30VDC
3A 120VAC
Max. Switching Voltage 240VAC/30VDC
Max. Switching Current 5A
Max. Switching Capacity 360VA/30W
Min. Allowing Load 5VDC 100mA
Electrical Performance Insulation Resistance (Initial) 1000mΩ (500VDC)
Dielectric Strength (Initial) Between Open Contacts 500VAC, 1 min
Between Coil & Contacts 1000VAC, 1 min
Operate Time ≤10ms
Release Time ≤5ms
Mechanical Performance Shock Resistance Functional 98m/s2(10g)
Destructive 980m/s2(100g)
Vibration Resistance 10Hz ~ 55Hz 1.5mm DA
Endurance Mechanical 1 x 107ops
Electrical 1A 240VAC 1 x 105ops (ON/OFF=1s/9s)
3A 120VDC 5 x 104ops (ON/OFF=1s/9s)
Operate Condition Ambient Temperature -25℃ ~ 70℃
Humidity 5% to 85%
Termination PCB (DIP Encapsulation)
Unit Weight 5g
Construction Plastic Sealed, Flux Proofed

Note: In order to maintain the initial performance parameters of the signal relay, please be careful not to drop it.

Dimension

Units: mm

Performance curves

Tips: Signal relay troubleshooting

In the process of circuit application, improper operation or other interference factors will lead to signal relay faults. Common faults of signal relays include fuse fusing, wire breaking, sealing-off, screw loosening, coil burnout, bad contact of contacts, bad contact of connectors, bad insulation between lines and mixed power supply of lines. The solutions of the signal relay faults are as follows.

  • Mixed line protection circuit
    Indoor and signal relay box environment is better, as long as strict construction technology is adopted, mixed line fault rarely occurs in the circuit, so it is no need to take mixed line protection measures. For the outdoor circuit, whether the cables or other wires are used as the connecting line, the possibility of mixed line failure is more likely to occur, and the mixed line protection circuit needs to be adopted.
  • Disconnection protection circuit
    Disconnection fault is far more than mixed fault. The closed circuit method is used to design the signal relay circuit in order to drop the signal relay to protect the circuit in the event of a disconnection fault.

Reviews